Pvc conduit fill table. Provides quick and easy results for the conduit fill percent per nec guidelines. Conduit fill tables nec table c conductor size awg kcmil thhn thwn size 14 12 10 8 6 4 3 2 1 10 20 30 40 250 300 350 400 500 600 750 2 emt 241 176 111 64 46 28 24 20 15 12 10 8 7 6 5 4 4 3 2 1 rmc 200 146 92 53 38 23 20 17 12 10 8 7 6 5 4 3 3 2 1 1 imc 211 154 97 56 40 25 21 17 13 11 9 7 6 5 4 4 3 3 2 1 40 193 141 89 51 37 22 19 16 12 10 8 7 6 4 4 3 3 2 1 1 80 170 124 78. 2272014 24426 pm. Information is provided as a guideline only.

The nec sets standards for the percent of volume that can safely be put into conduit. Conduit wire fill charts tables. Conduit fill calculator conduit fill is the percent of area inside the conduit taken up by the cables. This conduit fill table is used to determine how many wires can be safely put into non pvc conduit tubing or pipe.

The results show the allowable number of wires for each sizetype of conduit and wire based. The below chart is from table 1 in chapter 9 of the national electric code. Each column going up and down is a different gauge of wire. Each column going up and down is a different gauge of wire.

Chapman electric offers a selection of pipe and conduit to meet your electrical or underground project needs. Rigid pvc conduit schedule 80 table c9 rigid pvc conduit schedule 40 table c10 flexible metallic conduit table c3 liquidtight flexible metallic conduit table c7 liquidtight flexible nonmetallic conduit type fnmc b table c5 if you have any other questions see the nec code book or ask an ces. Each row going across is a different size of pvc conduit schedule 40 or 80. Maximum number of compact conductors in rigid pvc conduit schedule 40 and hdpe conduit based on table 1 chapter 9 view full width table c11.

This conduit fill table is used to determine how many wires can be safely put into pvc conduit tubing. Trade size interior diameter exterior diameter interior area exterior area interior volume per exterior volume per 12 062 in. Maximum number of conductors allowed by conduit size and wire gauge. Home resources calculators conduit fill calculator.

The results show the allowable number of wires for each sizetype of conduit and wire based on the 2020 nec code. Conduit fill chart twn75t 90 nylon. Maximum number of conductors or fixture wires in type a rigid pvc conduit based on table 1 chapter 9 view full width types rhh rhw and rhw 2 without outer covering. Percent of cross section of conduit and tubing for.

Calculate your conduit fill percentage. A great tool to help electricians engineers and contractors answer the question what size conduit do i use per. Check your local code.